Unit of Measure
Items
PSAN Series Display Type Pressure Sensor

PSAN Series Display Type Pressure Sensor

PSB Series Display Type Pressure Sensor

PSB Series Display Type Pressure Sensor

PSQ Series Dual Display Type Pressure Sensor

PSQ Series Dual Display Type Pressure Sensor

PSS Series Compact Pressure Sensor

PSS Series Compact Pressure Sensor
Brands N/A Autonics
Model N/A PSAN N/A PSB N/A PSQ N/A PSS
Type N/A Pressure Sensor
Power Supply N/A 12 - 24 VDC (ripple P-P: ≤ 10%) N/A 12 - 24 VDC ±10% (ripple P-P: ≤ 10%) N/A 12 - 24 VDC (ripple P-P: ≤ 10 %) N/A 12 - 24 VDC ±10% (ripple P-P: ≤ 10%)
Allowable Voltage Range N/A 90 to 110% of Rated Voltage N/A N/A 90 to 110% of Rated Voltage N/A
Current Consumption N/A ≤ 50 mA N/A ≤ 50 mA N/A ≤ 50 mA (analog output model: ≤ 70 mA) N/A Voltage output model: ≤ 15 mA
Control Output N/A Negative-Positive-Negative (NPN) open collector output Positive-Negative-Positive (PNP) open collector output model N/A Negative-Positive-Negative (NPN) open collector output Positive-Negative-Positive (PNP) open collector output model N/A Negative-Positive-Negative (NPN) Positive-Negative-Positive (PNP) open collector output N/A DC 4 -20 mA ±2% F.S.
Protection Circuit N/A N/A N/A N/A Reverse polarity protection circuit
Voltage Output N/A N/A N/A N/A 1 - 5 VDC ±2% F.S.
Analog Output Temperature Characteristic N/A N/A N/A N/A ≤ ±2% F.S. (in 0 to 50 ºC temperature range, at 25 ºC)
Insulation Resistance N/A N/A N/A N/A ≥ 50 MΩ (500 VDC megger)
Direct Current (DC) Load Voltage N/A ≤ 30 V N/A ≤ 30 V N/A ≤ 30 V N/A
Load Current N/A ≤ 100 mA N/A ≤ 100 mA N/A ≤ 100 mA N/A
Direct Current (DC) Residual Voltage N/A N/A N/A ≤ 2 V N/A
Residual Voltage N/A NPN: ≤ 1 VDC, PNP: ≤ 2 VDC N/A NPN: ≤ 1 VDC, PNP: ≤ 2 VDC N/A N/A
Hysteresis N/A According to output operation mode N/A Negative / Static: 1-digit (psi unit: 2-digit)
Compound: 2-digit
N/A Different by output operation mode (parameter) N/A
Dielectric Strength N/A Between the charging part and the case: 1,000 VAC 50/60 Hz for 1 minute N/A N/A Between the charging part and the case: 1,000 VAC 50/60 Hz for 1 minute N/A Between the charging part and the case: 2,000 VAC 50/60 Hz for 1 minute
Vibration N/A 1.5 mm amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours N/A 1.5 mm amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours N/A 1.5 mm amplitude at frequency of 10 to 55Hz in each X, Y, Z direction for 2 hours N/A 1.5 mm amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours
Ambient Temperature N/A -10 to 50 ºC, Storage: -20 to 60 ºC (No Freezing or Condensation) N/A -10 to 50 ºC, Storage: -20 to 60 ºC (No Freezing or Condensation) N/A -10 to 50 ºC, Storage: -20 to 60 ºC (No Freezing or Condensation) N/A 0 to 50 ºC, Storage: -10 to 60 ºC (No Freezing or Condensation)
Ambient Humidity N/A 30 to 80% RH, Storage: 30 to 80% RH (No Freezing or Condensation) N/A 35 to 85% RH, Storage: 35 to 85% RH (No freezing or Condensation) N/A 30 to 80% RH, Storage: 30 to 80% RH (No Freezing or Condensation) N/A 35 to 85% RH, Storage: 35 to 85% RH (No freezing or Condensation)
Features N/A
  • Pressure measurement of any gas, liquid or oil (except substances which may corrode stainless steel 304/316L)
  • Auto shift function: with change in the original pressure, the external input adjusts the determined level to match the change in pressure (only available in models with auto shift/hold function)
  • Hold function: hold current display value or control output
  • Forced output control mode for device testing and maintenance
  • One-touch connector type for easy wiring and maintenance
  • Zero-point adjustment function, peak value monitoring function, chattering prevention function
N/A
  • High accuracy digital pressure sensor
  • Bright red LED display (character height : 9.5 mm)
  • High display resolution
    • Negative pressure 0.1 kPa / standard pressure 0.1 kPa, 1 kPa / compound pressure 0.2 kPa
  • Unit conversion function
    • Negative, compound pressure: kPa, kgf/cm², bar, psi, mmHg, mmH2O, inHg
    • Standard pressure: kPa, kgf/cm², bar, psi
  • Various output modes: hysteresis mode, automatic sensitivity adjustment mode, independent 2-point output mode, window comparison output mode
  • Chattering prevention function (response time: 2.5 ms, 5 ms, 100 ms, 500 ms)
  • Analog output (1 - 5 VDC) scale function
  • Zero-point adjustment function
  • Peak value and low value hold function
  • Built-in reverse polarity protection circuit, overcurrent protection circuit
N/A
  • Pressure measurement of any gas, liquid or oil [fluid type] except substances which may corrode stainless steel 316L
  • Dual display for simultaneous display of process value (PV) and setpoint value (SV)
  • Secondary (SV) display : setpoint value, pressure unit, or display-OFF
  • Switch between NPN and PNP open collector output via parameter configuration
  • 3-Color main (PV) display (RUN mode : green/red, parameter setting mode : orange)
  • 12-Segment LCD display capable of diverse alphanumeric characters
  • Measurement range : -100.0 to 100.0 kPa /-100 to 1000 kPa (Pneumatic type : compound pressure, Fluid type : sealed gauge pressure)
  • Analog output : voltage (1-5VDC), current (DC 4-20mA)
  • Copy parameter settings function
  • External input : Auto-Shift, Remote, Hold (PSQ-models only)
  • Forced output control mode for device testing and inspection
  • Display resolution : 0.1 kPa /1 kPa (by model)
  • One-touch connector type for easy wiring and maintenance
  • Password lock for parameter configuration settings
N/A
  • Rated pressure range
    • Negative pressure (0 kPa to -101.3 kPa)
    • Positive pressure (0 kPa to 100.0 kPa / 0 kPa to 1000 kPa)
    • Compound pressure (-101.3 kPa to 100 kPa)
  • Compact size: W 11.8 mm × H 29.3 mm × L 24.8 mm (with pressure port)
  • Analog output: voltage (1 - 5 VDC), current (DC 4 - 20 mA)
  • Power supply: 12 - 24 VDC ±10%