Unit of Measure
Items
SR1 Series 1-Phase Solid State Relay (SSR) with Detachable Heatsink

SR1 Series 1-Phase Solid State Relay (SSR) with Detachable Heatsink

SR2/SR3/SRH2/SRH3 Series 2/3-Phase Solid State Relay (SSR) with Detachable/Integrated Heatsink

SR2/SR3/SRH2/SRH3 Series 2/3-Phase Solid State Relay (SSR) with Detachable/Integrated Heatsink

SRC1 Series 1-Phase Slim Solid State Relay (SSR) with Detachable Heatsink

SRC1 Series 1-Phase Slim Solid State Relay (SSR) with Detachable Heatsink

SRH1 Series Voltage Input Type 1-Phase Top/Bottom Terminal Solid State Relay (SSR) with Integrated Heatsink

SRH1 Series Voltage Input Type 1-Phase Top/Bottom Terminal Solid State Relay (SSR) with Integrated Heatsink

SRHL1 Series 1-Phase Right/Left Terminal Solid State Relay (SSR) with Integrated Heatsink

SRHL1 Series 1-Phase Right/Left Terminal Solid State Relay (SSR) with Integrated Heatsink
Brands N/A Autonics
Model N/A SR1 N/A SR2/SR3/SRH2/SRH3 N/A SRC1 N/A SRH1 N/A SRHL1
Type N/A Relay
Insulation Resistance N/A Input-output, input / output-case: ≥ 100 MΩ (500 VDC, Megger) N/A ≥ 100 MΩ (500 VDC, Megger) (input-output, input/output-case) N/A Input-output, input / output-case: ≥ 100 MΩ (500 VDC, Megger) N/A Input-output, input / output-case: ≥ 100 MΩ (500 VDC, Megger) N/A Input-output, input / output-case: ≥ 100 MΩ (500 VDC, Megger)
Indicator N/A Input Indicator (Green) N/A Input Indicator (Green), Alarm Indicator (Red) N/A Input Indicator (Green) N/A Input Indicator (Green) N/A Input Indicator (Green), Alarm Indicator (Red)
Vibration N/A 0.75 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 1 hour
Vibration (Malfunction) N/A 0.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 10 minutes
Shock N/A 300 m/s² (≈ 30 G) in each X, Y, Z direction for 3 times
Shock (Malfunction) N/A 100 m/s² (≈ 10 G) in each X, Y, Z direction for 3 times
Ambient Temperature N/A -30 to 80 ºC (in case of the rated input voltage VAC~: -20 to 70 ºC), storage: -30 to 100 ºC (No freezing or Condensation) N/A -30 to 80 ºC (in case of the rated input voltage 90 - 240 VAC~: -30 to 70 ºC), storage: -30 to 100 ºC (No freezing or Condensation) N/A -30 to 80 ºC (in case of the rated input voltage 90 - 240 VAC~: -20 to 70 ºC), storage: -30 to 100 ºC (No Freezing or Condensation) N/A -30 to 80 ºC (in case of the rated input voltage 90 - 240 VAC~: -20 to 70 ºC), storage: -30 to 100 ºC (No Freezing or Condensation) N/A -30 to 70 ºC, Storage: -30 to 100 ºC (No Freezing or Condensation)
Ambient Humidity N/A 45 ~ 85% RH, storage: 45 ~ 85% RH (No Freezing or Condensation)
Input Terminal Fixed Torque N/A 0.75 to 0.95 N·m
Features N/A
  • Compact, universal design for flexible installation
  • High heat dissipation efficiency with ceramic PCB
  • Zero cross turn-on, random turn-on models available
  • Input Indicator (green)
N/A
  • Two mounting hole types and sizes
  • Alarm function (overheat prevention): alarm indicator (red), disconnect output, alarm output
  • Improved dielectric strength: 4,000 VAC~ (some are 2,500 VAC~ model)
  • Rated input voltage : 4 - 30 VDC~ , 24 VAC~, 90 - 240 VAC~
  • Rated load voltage : 24 - 240 VAC~, 48 - 480 VAC~
  • Rated load current : 15 A, 30 A, 40 A, 50 A, 75 A
  • High heat dissipation efficiency with ceramic PCB and integrated heatsink
  • Zero cross turn-on/Random turn-on models available
  • Input indicator (green)
N/A
  • Slim, compact size (22.5 mm width)
  • High heat dissipation efficiency with ceramic PCB
  • Zero cross turn-on, random turn-on models available
  • Input Indicator (green)
N/A
  • High heat dissipation efficiency with ceramic PCB and integrated heatsink
  • Input Indicator (green)
  • DIN rail mount or panel mount installation
  • Zero cross turn-on / Random turn-on models available
N/A
  • Rated input voltage : 10 - 30 VDC, 90 - 240 VAC~
  • Rated load voltage : 24 - 240 VAC~, 48 - 480 VAC~
  • Rated load current : 10 A, 15 A, 20 A, 25 A, 40 A
  • Zero cross turn-on / Random turn-on models available
  • Input indicator (green)
  • Overheat prevention function
    • Rated load current 10 / 15 / 20 / 25 A: alarm indicator (red)
    • Rated load current 40 A: alarm output indicator (red), alarm output
    • DIN Rail or panel mount installation